UV2D Cabin Module

Cabin switches and sensors, on the bus

UV2D is a CAN module fitted inside the cab. It reads the operator’s switches and the cabin’s sensors and brings them into the machine’s control system over a single bus cable.

A cab typically holds dozens of switches, potentiometers and indicator lamps, each of which would otherwise need its own wire running all the way to the control system. UV2D gathers them in one place: the module is mounted in the cab, near the switches, and only the CAN bus and the supply voltage leave for the chassis. The harness gets shorter, there are fewer joints, and a fault is easier to find.

UV2D is part of the Usevolt control system, and like all our controllers it is configured through the UV0D touchscreen display — with no computer and no separate programming tools.

Technical specifications

Supply voltage 8 – 30 V DC
Protection Over-voltage and reverse-voltage. An external 20 A fuse is required.
Current consumption Logic 40 mA
Outputs 4 x proportional high-side PWM output with current sense
Output max current 2300 mA
Inputs 4 x analog voltage input, 0 – 5 V
7 x digital input pair, 30 V tolerant
Sensor supplies VDD 700 mA and 5 V 300 mA
Communications 1 x CAN bus 2.0B, CANopen protocol
Connector Superseal 4-1437290-0, golden contacts 3-1447221-4 (34-pin)
Microcontroller 32-bit ARM Cortex-M3
Memory 256 kB application flash, 36 kB RAM
IP rating IP67
Material Aluminium
Weight 320 g
Storage temperature -30 … +80 °C
Configuring Through the UV0D display

Connector pin-out

The UV2D 34-pin connector pin-out: power supply, CAN, sensor supplies, analog inputs, digital inputs and proportional outputs
The UV2D 34-pin connector pin-out.

Downloads

Datasheet (PDF)
Dimensions (PDF)

To ask about UV2D and fitting it to your machine, see the contact page.